You are here: Main






















Whether you're calibrating instruments, troubleshooting a problem, or running routine maintenance, the Fluke 754 with HART® communication can help you get the job done faster. It does so many different tasks, so quickly and so well, it's the only process calibrator you need to carry. This rugged, reliable integrated communicating calibrator is ideal for calibrating, maintaining, and troubleshooting HART and other instrumentation.
The 754 is a power multifunction documenting calibrator that you can use to download procedures, lists, and instructions created with software; or upload data for printing, archiving, and analysis. The powerful built-in HART interface is capable of performing nearly all the day-to-day tasks you now perform with a separate communicator.
In fact, the 754 does the work of several tools. It sources, simulates and measures pressure, temperature, and electrical signals with one rugged, hand-held device. For documentation, the 754 automates calibration procedures and captures your data. And, of course, it helps you meet rigorous standards like ISO 9000, FDA, EPA and OSHA regulations. Plus, the new improved graphical screen, Li-Ion battery for longer life, USB port, and accessories help you work smarter and faster.

The FREJA and SMRT Digital Twin is the first of it’s type to be created and is a functional digital twin of Megger's relay test systems, FREJA and SMRT. This pioneering technology enables you to virtually test Siemens SIPROTEC 5 devices through Siemens’ cloud-based SIPROTEC DigitalTwin. The relay tests are performed online, before the physical devices are accessible, and with tested and approved protection settings, only a subset of the tests need to be repeated on the physical devices to ensure correct input and output hardware and connections.
Dear Customers,
We would like to thank you for spending your time visiting our booth at the Electrical & Power Indonesia Exhibition 2023, held in JIEXPO Kemayoran - Jakarta. It was our pleasure and honor as we enjoyed many inspiring conversations. The exhibition gave us the opportunity to showcase our successful collections and new additions, which generated great interest.
For further inquiries or in case you want more information about our products, please feel free to email us.
Best Regards,
The Electrical Testing Expert Team
Direct connection
Induced with induction clamp
Merytronic PI-3 MV & LV cable identifier is a robust, user-friendly, and advanced digital tool. It helps users easily identify any de-energized electric cable and its phases, among multiple conductors, in substations, trenches, manholes, panels, aerial/underground conversions, etc
The transmitter includes three inductive clamps (or crocodiles). Therefore, it can detect each one of the phases of a feeder without changing the transmitter connection. It also helps to identify both de-energized cables prior to being cut and open cables (once they have already been cut) to join the phases of both sides correctly

>>>>
The SPG5-1000-1 is a comprehensive all-in-one-box fault locating solution, tailored for testing, identifying, converting, prelocating, and pinpointing faults in low-voltage cable installations. It effectively handles a wide variety of cable faults: from flashing and non-flashing to high and low resistance, intermittent, main insulation, and sheath faults.
Prioritising user convenience, the SPG5-1000-1 is fully automated and features an intuitive software interface, eliminating most user interventions known from manual analogue instruments. The controller actuates motorised switches so that the unit auto-adjusts to the correct settings based on user input. Simplifying the operation further, a single “turn and click” rotary knob ensures easy accessibility for users of all experience levels.
Utilising the integrated ICEplus method for HV prelocation, the SPG5-1000-1 accurately and precisely locates faults in both unbranched point-to-point low-voltage cables and branched low-voltage networks with T- or Y-joints. ICEplus is a transient prelocation method that evaluates the oscillating current component of a propagating travelling wave which was previously created by capacitor discharge into the cable. Notably, unlike TDR and ARM, this method is unaffected by common issues of attenuation and reflections at T- or Y-junctions, ensuring consistent prelocation regardless of the network’s configuration.
>>>>>>>
Toolbox philosophy: Identification, prelocation, pinpointing and conversion of faults all in one unit
Safety interlocks for monitoring of station earth and touch potentials (F-U), as well as earth connections (F-Ohm)
Fully automatic operation of all modes via motorised switching
Software-based user interface with single “turn & click” rotary knob control
ICEplus transient prelocation method for normal unbranched LV cables as well as for branched LV networks
DC test (DC hi-pot) and burning up to 5 kV, surging (thumping) up to 4 kV, delivers 1000 J

The MS5000 (Metrysense5000) Smart Grid medium voltage sensor for overhead line networks (4 to 140 kV) provides real-time grid information, giving you unprecedented visibility of your distribution grids through the accurate identification of high impedance faults and predictive analytics for deteriorating network components. It has been designed for FLISR (fault location, isolation, and service restoration), grid analytics, power quality, and flow monitoring.

The AIAcompact is a portable instrument for in-service acoustic and electric (UHF) partial discharge measurements on high voltage assets such as:
To be suitable for all these applications, the instrument adapts to a variety of piezoelectric acoustic sensors and pre- processing units. It can be used with acoustic sensors and external ultra high frequency sensors as well as embedded UHF sensors of the tested asset.
Because of its built-in battery and its standalone capability the AIAcompact can even be used for on-site testing in environments where no mains supply is available.
For a convenient remote control of the device, the USB interface allow the connection to a PC or laptop with the optional AIAcompact software installed.
Every AIAcompact comes with a built-in four-channel multiplexer, which allows switching between four input channels. Buttons at the panel of the instrument enable you to directly select one of the four signal sources. As a result, the partial discharge signal and the voltage signal are split and can be selected separately. All settings, e.g., input and display mode, are stored individually for each channel.